HPLC Columns
HPLC Columns
- (1)
- (9)
- (281)
- (588)
- (1)
- (178)
- (3)
- (857)
- (1)
- (61)
- (33)
- (1)
- (8)
- (762)
- (171)
- (46)
- (6)
- (5)
- (1)
- (5)
- (5)
- (14)
- (622)
- (11)
- (2)
- (1)
- (30)
- (6)
- (17)
- (1)
- (3)
- (5)
- (29)
- (8)
- (1)
- (2)
- (5)
- (14)
- (5)
- (4)
- (2)
- (10)
- (100)
- (2)
- (1)
- (233)
- (4)
- (1)
- (2)
- (3)
- (196)
- (678)
- (1)
- (1)
- (146)
- (1)
- (2)
- (31)
- (8)
- (83)
- (2)
- (448)
- (1)
- (106)
- (2)
- (408)
- (28)
- (945)
- (2)
- (2)
- (2)
- (92)
- (2)
- (2)
- (11)
- (1)
- (20)
- (35)
- (2)
- (1)
- (21)
- (14)
- (5)
- (23)
- (72)
- (96)
- (319)
- (41)
- (8)
- (8)
- (4)
- (37)
- (39)
- (17)
- (197)
- (10)
- (6)
- (1)
- (820)
- (2)
- (50)
- (2)
- (1,813)
- (10)
- (2)
- (63)
- (3)
- (23)
- (6)
- (5)
- (17)
- (1)
- (1)
- (778)
- (2)
- (2)
- (3)
- (66)
- (1)
- (421)
- (471)
- (213)
- (224)
- (107)
- (13)
- (601)
- (5)
- (68)
- (16)
- (5)
- (8)
- (6)
- (88)
- (172)
- (7)
- (4)
- (6)
- (16)
- (197)
- (1)
- (10)
- (2)
- (14)
- (104)
- (6)
- (2)
- (11)
- (2)
- (1)
- (9)
- (40)
- (1)
- (132)
- (35)
- (12)
- (187)
- (2)
- (1)
- (2)
- (13)
- (188)
- (48)
- (1)
- (11)
- (122)
- (2)
- (8)
- (2,493)
- (9)
- (21)
- (12)
- (10)
- (8)
- (2)
- (96)
- (11)
- (47)
- (13)
- (4)
- (4)
- (4)
Filtered Search Results
Thermo Scientific™ Aquasil™ 5μm C18 HPLC Columns, 5?m Particle Size
Thermo ScientificTM AquasilTM 5μm C18 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 12% |
Stationary Phase | C18 |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 310 m²/g |
USP Type | L1 |
Column Format | Analytical Column |
Thermo Scientific™ Syncronis™ aQ C18 Polar Endcapped HPLC Columns
Use for predictable HPLC separations of compounds in highly aqueous mobile phases.
Pore Size | 100 Å |
---|---|
Carbon Load | 19% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Polar |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 320 m²/g |
USP Type | L1 |
Thermo Scientific™ μPAC™ Neo HPLC Columns
Learn more about your proteome samples with Thermo Scientific™ μPAC™ Neo HPLC columns.
Pore Size | 100 to 300 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silicon Chip |
pH | 1.5 to 7 |
Max. Pressure | 6526 psi (450 bar) |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
USP Type | L1 |
Macherey-Nagel™ Nucleoshell™ Ammonium/Sulfonic Acid Modified Silica HILIC HPLC Column, 2.7 μm, 4.6 mm x 50 mm
Column Format: Analytical Column; Carbon Load: 1.3%; Pore Size: 90 Å; Column Phase: HILIC
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
Carbon Load | 11% |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ PepMap™ Neo Trap Cartridge
Use the Thermo Scientific™ PepMap™ Neo Trap Cartridge with PepMap™ Neo UHPLC Columns to filter impurities from your peptide mapping samples.
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
Pore Size | 120 Å |
---|---|
Carbon Load | 10% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Hypercarb™ Porous Graphitic Carbon HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for enhanced retention of polar compounds and separation of structurally related analytes with stability at pH extremes and high temperature.
Thermo Scientific™ μPAC™ Neo Low-Load Trapping Columns
Combine μPAC™ Neo trapping columns with μPAC™ Neo low-load HPLC columns for optimal performance of bottom-up proteomics experiments.
Thermo Scientific™ Accucore™ 150 Amide HILIC HPLC Columns
Designed for the separation of hydrophilic biomolecules in HILIC mode—an excellent choice for glycan separations.
Thermo Scientific™ Hypersil™ APS-2 Amino HPLC Columns
Analyze sugars with this versatile amino propyl phase of Thermo Scientific™ Hypersil™ APS-2 Amino LC Columns.
Pore Size | 120 Å |
---|---|
Carbon Load | 2% |
Stationary Phase | Amino (NH2) |
Temperature | 60°C |
Phase | Reversed Phase, Normal Phase, Ion Exchange, HILIC |
Endcapped | No |
Surface Area | 170 m²/g |
USP Type | L8 |
Thermo Scientific™ Accucore™ aQ C18 Polar Endcapped HPLC Columns
Use this column, with its specially designed solid core, for the separation of compounds in highly aqueous mobile phases.
Pore Size | 80 Å |
---|---|
Stationary Phase | C18 |
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Polar |
Column Type | Reversed Phase |
Surface Area | 130 m²/g |
Max. Pressure | 14500 psi (1000 bar) |
Particle Size | 2.6 μm |
Carbon Load | 9% |
Packing Material | Spherical, Solid Core, Ultrapure Silica |
pH | 2 to 9 |
Particle Shape | Spherical Solid Core |
Product Line | Accucore |
USP Type | L1 |
Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns
Use as a robust, general-purpose column for QC/QA applications. They are high-quality, base-deactivated, fully endcapped, have similar C18 selectivity but slightly less retentive.
Pore Size | 130 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L7 |