Protein Purification Reagents and Kits

Protein Purification Reagents and Kits
- (1)
- (84)
- (3)
- (23)
- (3)
- (3)
- (1)
- (1)
- (2)
- (2)
- (2)
- (21)
- (1)
- (4)
- (3)
- (1)
- (6)
- (10)
- (33)
- (56)
- (4)
- (3)
- (3)
- (42)
- (1)
- (1)
- (3)
- (1)
- (4)
- (9)
- (5)
- (3)
- (10)
- (11)
- (2)
- (3)
- (3)
- (5)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (62)
- (2)
- (2)
- (5)
- (1)
- (2)
- (1)
- (1)
- (4)
- (6)
- (1)
- (53)
- (2)
- (12)
- (7)
- (2)
- (1)
- (4)
- (1)
- (1)
- (6)
- (3)
- (7)
- (1)
- (9)
- (213)
- (29)
- (2)
- (1)
- (4)
- (3)
- (3)
- (32)
- (1)
- (1)
- (2)
- (51)
- (73)
- (2)
- (2)
- (1)
- (6)
- (11)
- (10)
- (5)
- (2)
- (28)
- (1)
- (3)
- (5)
- (4)
- (1)
- (99)
- (107)
- (2)
- (16)
- (1)
- (6)
- (9)
- (39)
- (17)
- (6)
- (6)
- (38)
- (5)
- (7)
- (3)
- (6)
- (11)
- (31)
- (21)
- (4)
- (8)
- (6)
- (62)
- (3)
- (11)
- (2)
- (1)
- (2)
- (1)
- (11)
- (9)
- (6)
- (2)
- (1)
- (15)
- (14)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (2)
- (1)
- (2)
- (12)
- (10)
- (3)
- (1)
- (2)
- (1)
- (2)
- (5)
- (1)
- (1)
- (2)
- (1)
- (4)
- (4)
- (5)
- (3)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (2)
- (1)
- (4)
- (1)
- (13)
- (2)
- (1)
- (1)
- (9)
- (1)
- (1)
- (1)
- (10)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (5)
Filtered Search Results

Thermo Scientific™ HisPur™ Ni-NTA Spin Plates
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
Thermo Scientific™ HisPur™ Ni-NTA Spin Columns, 1 mL
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
Thermo Scientific™ HisPur™ Cobalt Resin
Gently purify His-tagged recombinant fusion proteins using cobalt (Co2+) immobilized metal chelate affinity (IMAC) beads, spin columns and plates.
Stationary Phase | Metal Chelate, Divalent Cobalt |
---|---|
Type | Resin |
Target | His-Tagged Protein |
Content And Storage | Store at 4°C |
Format | Bottle |
Protein Form | Recombinant |
Form | Liquid Suspension |
Column Type | Affinity, Agarose Resin |
Product Line | HisPur™ |
Thermo Scientific™ HisPur™ Ni-NTA Superflow Agarose
Perform FPLC purification of poly-histidine-tagged proteins with this nitrilotriacetic acid (NTA) modified Superflow 6 support charged with divalent nickel (Ni+2).
Stationary Phase | Divalent Nickel, Metal Chelate |
---|---|
Type | Agarose |
Target | His-Tagged Protein |
Content And Storage | Store at 4°C |
Format | Bottle |
Form | Liquid Suspension |
Column Type | Affinity, Agarose Resin |
Capacity (Metric) | 20 mg His-Tagged GFP Binding per mL Resin |
Product Line | HisPur™ |
Thermo Scientific™ HisPur™ Ni-NTA Chromatography Cartridges, 1 mL
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
Stationary Phase | Divalent Nickel, Metal Chelate |
---|---|
Type | Chromatography Cartridge |
Target | His-Tagged Protein |
Content And Storage | Store between 4°C and 8°C. Do not freeze. |
Column Type | Affinity, Agarose Resin |
Product Line | HisPur™ |
Thermo Scientific™ Mitochondria Isolation Kit for Cultured Cells
Isolate intact mitochondria from cultured mammalian cell samples in about 40 minutes with this versatile, benchtop microcentrifuge-based fractionation kit.
Thermo Scientific™ Pierce™ Glutathione Agarose
Purify GST-tagged recombinant fusion proteins from cell lysates using glutathione (GSH) beaded agarose affinity purification resins, spin columns and plates.
Stationary Phase | Glutathione |
---|---|
Type | Agarose |
Content And Storage | Upon receipt store at 4°C. |
Format | Bottle |
Protein Form | Recombinant |
Column Type | Affinity, Agarose Resin |
Capacity (Metric) | 40 mg Purified Recombinant GST Protein Binding per mL Resin |
Product Line | Pierce™ |
Thermo Scientific™ Pierce™ NHS-Activated Agarose, Dry
N-Hydroxysuccinimide ester resin and columns to covalently immobilize proteins, peptides and other amine-containing ligands for affinity purification.
Stationary Phase | NHS Ester |
---|---|
Type | Agarose |
Target | Antibody, Protein, Peptide, Ligand |
Content And Storage | Upon receipt store dry resin at -20°C. Product is shipped in an ice pack. |
Format | Vial |
Protein Form | Recombinant |
Column Type | Affinity, Agarose Resin |
Capacity (Metric) | ≥25 mg per mL Coupling |
Product Line | Pierce™ |
Thermo Scientific™ AminoLink™ Plus Immobilization Kit, 2 mL
Covalently couple antibodies and other proteins via primary amines (-NH2) for affinity purification with these aldehyde-activated agarose beads.
Stationary Phase | Aldehyde |
---|---|
Type | Immobilization Kit |
Target | Antibody, Proteins through Primary Amine |
Format | Spin Column |
Column Type | Affinity, Agarose Resin |
Capacity (Metric) | 2 to 40 mg of protein Immobilization per Column |
Sufficient For | 2 to 40 mg of Protein per Column |
Product Line | AminoLink™ |
Invitrogen™ Ni-NTA Agarose
Nickel-charged affinity resin that can be used to purify recombinant proteins containing a polyhistidine (6xHis) sequence
Type | Agarose |
---|---|
Stationary Phase | Ni-NTA |
Content And Storage | The Ni-NTA resin is pre-charged and able to bind up to 50 mg of recombinant protein per 1 ml of resin. It is provided as a 50% slurry in 30% ethanol. The resin will appear blue in color when charged with Ni2+ . Store at +4°C. Ni-NTA resin is guaranteed stable for 6 months when properly stored. |
Form | Suspension |
Column Type | Affinity Column |
Thermo Scientific™ AminoLink™ Coupling Resin
Covalently immobilize proteins and antibodies by lysine residues or other primary amines (-NH2) via reductive amination with these aldehyde-activated agarose beads.
Stationary Phase | Aldehyde |
---|---|
Type | Resin |
Target | Antibody, Proteins through Primary Amine |
Content And Storage | Store at 4°C. |
Format | Bottle |
Column Type | Affinity, Agarose Resin |
Product Line | AminoLink™ |
Thermo Scientific™ HisPur™ Ni-NTA Spin Columns, 0.2 mL
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
Thermo Scientific™ Pierce™ Glutathione Spin Columns, 3 mL
Purify GST-tagged recombinant fusion proteins from cell lysates using glutathione (GSH) beaded agarose affinity purification resins, spin columns and plates.
Thermo Scientific™ Pierce™ Glutathione Spin Columns, 0.2 mL
Purify GST-tagged recombinant fusion proteins from cell lysates using glutathione (GSH) beaded agarose affinity purification resins, spin columns and plates.
Thermo Scientific™ Detergent Removal Spin Columns & Plates
Rapidly eliminate high concentrations of detergents with minimal sample loss with detergent removal resins. Thermo Scientific HiPPR (High Protein and Peptide Recovery) resin is recommended for protein concentrations up to 100 μg/mL, while Thermo Scientific Pierce resin is suitable for concentrations over 100 μg/mL.
Stationary Phase | Proprietary Ligand |
---|---|
Column Type | Proprietary Resin, Affinity |
Purification Target | Detergent Removal |