Thermo Scientific Choice™ PES (Polyethersulfone) Syringe Filters
Use Choice PES (Polyethersulfone) Syringe Filters for ion chromatography samples, and filtration of tissue cultures, proteins, nucleic acids, and high-temperature liquids.

Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | PES |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |
Thermo Scientific Choice™ PVDF (Hydrophilic) Syringe Filters
Use Choice PVDF (hydrophillic) Syringe Filters for general biological filtration, especially when high protein recovery is desired. They do not require pre-wetting.

Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | PVDF (Hydrophilic) |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |
Thermo Scientific™ Target2™ Nylon Syringe Filters
Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust nylon syringe filters. Ideal for general HPLC use.

Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Polypropylene |
Material (Membrane) | Nylon |
Quantity | 100/Pk. |
Certifications/Compliance | Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. |
For Use With (Application) | HPLC, SPE |
Sterility | Non-sterile |
Product Line | Target2 |
Thermo Scientific Choice™ PTFE (Hydrophobic) Syringe Filters
Use Choice PTFE Hydrophobic Syringe Filters for filtration of aggressive organic, highly basic or hot solutions.

Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | PTFE (Hydrophobic) |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |
Cytiva Whatman™ 30mm Puradisc™ Nonsterile Cellulose Acetate Syringe Filters
Exhibit very low protein binding, so they are suitable for protein recovery applications. Whatman™ 30mm Puradisc™ Nonsterile Cellulose Acetate Syringe Filters are hydrophilic, making them functional with aqueous and alcoholic media despite having limited solvent resistance.

Type | Puradisc Syringe Filter |
---|---|
Dimensions (L x W x H) | 26 x 34 mm |
Diameter (Metric) | 30 mm |
Inlet Style | Female Luer Lock |
Housing Material | Polycarbonate (PC) |
Material (Membrane) | Cellulose Acetate |
Volume (Metric) | Up to 100 mL |
Pressure Rating | 6.9 bar (100 psi) |
For Use With (Application) | Designed for aqueous sample; Filtration of protein-containing solutions w/minimal protein loss |
Hold up Volume (After Air Purge) | <50 μL |
Filtration Area | 5.7 cm2 |
Cytiva Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa
Processes sample loads in one-third the time. Whatman™ Mini-UniPrep™ Syringeless Filters with Preslit Septa provide a faster and easier way to remove particulates from samples being prepared for HPLC and UHPLC analysis.

For Use With (Application) | Routine HPLC/UHPLC analysis; Composite assays; Content uniformity; Protein precipitation; Solubility testing; Dissolution testing; Sample filtration; Standard robotics on HPLC instruments with sensitive needles, allowing for higher throughput; Light sen |
---|
Cytiva Acrodisc™ Syringe Filters with Supor™ Membrane, Sterile
Sterile Acrodisc syringe filters featuring Supor™ membrane for high throughputs, fast filtration, and low protein binding. Available in 13 mm, 25 mm and 32 mm sizes, with pore sizes ranging from 0.1 μm to 5.0 μm.

Material (Membrane) | PES |
---|---|
Sterility | Sterile |
Cytiva Acrodisc™ Syringe Filters with PTFE Membrane and Minispike Outlet
Universal membrane syringe filters for all of your analytical filtration requirements.

Outlet Style | Minispike Outlet |
---|---|
Diameter (Metric) | 13 mm |
Housing Material | Polypropylene |
Material (Membrane) | PTFE |
Temperature (Metric) Max | 100°C |
Hold up Volume (After Air Purge) | <14 μL |
Sterility | Non-sterile |
Filtration Area | 1 cm2 |
Fisherbrand™ ProFill HPLC Syringe Filters, Glass Fibre membrane
HPLC performance tested
Sartorius Minisart™ RC Syringe Filters
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More

Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Combines rapid small volume particle removal filtration with maximum user convenience. Sartorius Minisart™ RC Syringe Filters utilize a regenerated cellulose membrane for clarification of small volume samples. Choose from 0.2 and 0.45μm pore sizes in 15, 25 and 4mm diameter filters.
Disposable | Single-use |
---|---|
Type | Syringe Filter |
Outlet Style | Male Luer Slip |
For Use With (Equipment) | Syringe |
Inlet Style | Female Luer Lock |
Housing Material | Polypropylene |
Material (Membrane) | Regenerated Cellulose |
Packaging | Bulk |
Pressure Rating | 4.5bar |
Filter Type | Syringe Filter |
Sterility | Non-sterile |
Thermo Scientific™ Titan3™ PTFE (Hydrophobic) Syringe Filters
Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust hydrophobic PTFE syringe filters.
Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Polypropylene |
Material (Membrane) | PTFE (Hydrophobic) |
Certifications/Compliance | Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified PTFE, with Polypropylene Support . |
Sterility | Non-sterile |
Product Line | Titan3 |
Thermo Scientific Choice™ Polypropylene (PP) Syringe Filters
Use Choice Polypropylene Syringe Filters as an economic solution to filtration of biological samples, and for filtration of aggressive organic solutions.
Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | Polypropylene (Hydrophilic) |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
Material | Polypropylene |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |
Thermo Scientific Choice™ PTFE (Hydrophilic) Syringe Filters
Use Choice PTFE Hydrophilic Syringe Filters to filter aggressive organic, highly basic or hot solutions. They can filter aqueous solutions without pre-wetting.
Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | PTFE (Hydrophilic) |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |
Thermo Scientific Choice™ Cellulose Acetate (CA) Syringe Filters
Remove interfering materials and fine particles. Use Thermo Scientific™ Choice™ Cellulose Acetate Syringe Filters for filtration of tissue culture media and sensitive biological samples.
Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | Cellulose Acetate |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |
Thermo Scientific Choice™ Nylon Syringe Filters
Use Thermo Scientific™ Choice™ Nylon Syringe Filters as the economic option for most general laboratory filtration, and for filtration of most HPLC samples.
Disposable | Single-use |
---|---|
Type | Syringe Filter |
Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
Material (Membrane) | Nylon |
Quantity | 100/Pk. |
Pressure Rating | 90 psi |
For Use With (Application) | HPLC, SPE |
Prefilter | No |
Sterility | Non-sterile |
Product Line | Choice |