missing translation for 'onlineSavingsMsg'
Learn More
Thermo Scientific™ Pierce™ LAL Chromogenic Endotoxin Quantitation Kit Product Code.: 12117850

Thermo Scientific™ Pierce™ LAL Chromogenic Endotoxin Quantitation Kit

Codice prodotto. 12117850 Sfoglia Tutto Thermo Scientific Prodotti
50 Tests, 1 set
missing translation for 'orderingAttributeHoverText'
Quantity:
50 Tests
missing translation for 'unitSize'
1 set
Questo articolo non è restituibile. Consulta la politica di reso

Product Code. 12117850

Brand: Thermo Scientific™ 88282

This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
View alternative products

Questo articolo non è restituibile. Consulta la politica di reso

Accurately measure endotoxin levels (LPS, lipopolysaccharides) in protein, peptide or antibody samples using our Limulus Amebocyte Lysate (LAL) assay.

The Thermo Scientific™ Pierce LAL Chromogenic Endotoxin Quantitation Kit measures the amount of endotoxin in a protein, peptide or antibody sample using the Limulus Amebocyte Lysate (LAL) assay.

The endotoxin concentration in a sample is measured using the Pierce LAL Chromogenic Endotoxin Quantitation Kit via a chromogenic signal generated in the presence of endotoxins. Samples can be measured on a microplate absorbance reader at 405nm. A standard curve is created using the E. coli endotoxin standard included with each kit to calculate endotoxin levels as low as 0.1 EU/mL. Protein and antibody samples can be assayed in as little as 30 minutes. Determining endotoxin levels is important to assess the efficiency of endotoxin removal methods and prevent endotoxic shock, inflammation and/or sepsis in tissue culture cells and animals injected with endotoxin-contaminated proteins.

Highlights:

  • Sensitive—detect as little as 0.1 EU/mL

  • Fast—perform this assay in 30 minutes

  • Economical—assay requires only 10ÎĽL of a protein sample

  • Accurate—E. coli O111:B4 standard in each kit enables accurate endotoxin quantitation

  • Versatile—405nm absorbance reading is compatible with common ELISA plate readers

Recommended for:

Quantitation of endotoxin levels in a protein, peptide or antibody solution

TRUSTED_SUSTAINABILITY

Specifica

Content And Storage Upon receipt store at 4°C. Product shipped with an ice pack.
Assay [other]
Detection Method Colorimetric
For Use With (Equipment) Spectrophotometer, Microplate Reader
Product Line Pierce™
Quantity 50 Tests
For Use With (Application) Solution-Based Detection, Absorbance
Target Not Target-Specific
Type Endotoxin Quantitation Kit
Format Kit

Certificates

A lot number is required to show results for certificates. To find your lot number on previous orders use our order status area.

5 results found
Lot Number Certificate Type Date Product Code
Lot NumberWC325809 Certificate TypeCertificate of Analysis Date05/03/2021 Product Code88282
Lot NumberVJ312731 Certificate TypeCertificate of Analysis Date31/10/2020 Product Code88282
Lot NumberVH310729 Certificate TypeCertificate of Analysis Date29/08/2020 Product Code88282
Lot NumberVG301696 Certificate TypeCertificate of Analysis Date10/07/2020 Product Code88282
Lot NumberVC298982 Certificate TypeCertificate of Analysis Date03/04/2020 Product Code88282
Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto
Thermo Scientific™ Pierce™ LAL Chromogenic Endotoxin Quantitation Kit >

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformitĂ  con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato