Thermo Scientific™ TraceGOLD™ TG-225MS GC Columns

Achieve higher thermal stability and increased efficiency using these columns.

2251.79 DKK - 8649.47 DKK

Specifications

Stationary Phase TraceGOLD™ TG-225 MS
USP Type G7, G19
Max. Temperature 220/240°C
Polarity Polar
View More Specs

Products 21
Product Code Brand Length (Metric) Diameter (Metric) Inner Film Thickness Price Quantity & Availability  
Product Code Brand Length (Metric) Diameter (Metric) Inner Film Thickness Price Quantity & Availability  
10575435
View Documents
Thermo Scientific™
26083-1300
15 m 0.25 mm 0.25 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10712537
View Documents
Thermo Scientific™
26083-1310
15 m 0.32 mm 0.25 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10704837
View Documents
Thermo Scientific™
26083-1420
30 m 0.25 mm 0.25 μm
4938.81 DKK
Each
Estimated Shipment: 16-01-2025
to see stock.
Add to basket
 
10209614
View Documents
Thermo Scientific™
26083-1430
30 m 0.32 mm 0.25 μm
5468.49 DKK
Each
Estimated Shipment: 20-01-2025
to see stock.
Add to basket
 
10714837
View Documents
Thermo Scientific™
26083-1440
30 m 0.53 mm 0.25 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10350825
View Documents
Thermo Scientific™
26083-1540
60 m 0.25 mm 0.25 μm
8649.47 DKK
Each
Estimated Shipment: 22-01-2025
to see stock.
Add to basket
 
10506385
View Documents
Thermo Scientific™
26083-2110
15 m 0.25 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10703687
View Documents
Thermo Scientific™
26083-2120
15 m 0.32 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10713687
View Documents
Thermo Scientific™
26083-2130
15 m 0.53 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10219664
View Documents
Thermo Scientific™
26083-2230
30 m 0.25 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10108094
View Documents
Thermo Scientific™
26083-2240
30 m 0.32 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10585435
View Documents
Thermo Scientific™
26083-2250
30 m 0.53 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10555625
View Documents
Thermo Scientific™
26083-2350
60 m 0.25 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10381545
View Documents
Thermo Scientific™
26083-2360
60 m 0.32 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10391545
View Documents
Thermo Scientific™
26083-2370
60 m 0.53 mm 0.5 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10361405
View Documents
Thermo Scientific™
26083-2850
15 m 0.32 mm 1 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10744457
View Documents
Thermo Scientific™
26083-2860
15 m 0.53 mm 1 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10458104
View Documents
Thermo Scientific™
26083-2970
30 m 0.32 mm 1 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10754457
View Documents
Thermo Scientific™
26083-2980
30 m 0.53 mm 1 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10361025
View Documents
Thermo Scientific™
26083-3090
60 m 0.32 mm 1 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
10117384
View Documents
Thermo Scientific™
26083-3100
60 m 0.53 mm 1 μm This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
N/A
Description

Description

Achieve higher thermal stability and increased efficiency using the Thermo ScientificTM TraceGOLDTM TG-225MS GC Columns.

Engineered for Superior Performance

  • Polar phase, 50% cyano propylmethyl/50% phenylmethyl polysiloxane
  • Innovative deactivation process for siloxane to reduce tailing and improves efficiency over comparable columns
  • Equivalent to USP G7, G19 phases


Applications:

  • Fatty acid methyl esters (FAMEs)
  • Carbohydrates
  • Sterols
  • Flavor compounds


A Leap Forward in Column Performance with Low Bleed and Superior Inertness

  • This low-bleed, stable column produces consistent results, and the low baseline noise enables improved limits of detection with enhanced resolution of low-level analytes.
  • Minimizing column bleed extends column lifetime, leading to higher productivity.
  • Reducing column bleed increases reproducibility of the stationary phase over time, resulting in greater run-to-run and batch-to-batch reproducibility.
  • Superior inertness ensures excellent peak shape and sensitivity, especially for highly active or difficult-to-analyze compounds.


Recommended For:

  • Alditol acetates (sugars)
  • FAMEs
  • Alternative Uses:
  • Ketones
  • Similar To:
  • Rtx™-225
  • DB-225
  • HP-225
  • SPB™-225
Specifications

Specifications

TraceGOLD™ TG-225 MS
G7, G19
220/240°C
Polar
Videos
SDS
Documents

Documents

Product Certifications

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.