Water Purification
Water Purification
Devices, filters, cartridges, accessories, and other supplies for use in the purification of water. Products include consumables and replacement parts for use with a variety of water purification systems.
Source or feed water may be tap water, water that is pre-treated by the system, or pretreated water that is drawn from a reservoir or tank. Water systems typically produce water rated as Type I, II, III, or IV.
Type I or ultrapure Type I water is defined by resistivity and TOC levels (total organic compounds, measured in parts per billion (ppb). Type I water is required for ICPMS, AAS, FAAS, GFAAS, HPLC, IC, and ICPAES methods, molecular biology, cell and tissue culture, electrochemistry, and electrophoresis.
Type II water is suitable for ELISA and RIA test methods, buffer and reagent preparation, and spectrophotometry. It also has a specific requirement for resistivity. Type III water is used for media preparation, glassware washing and rinsing, and other non-critical applications. Type IV water is typically used as feed water for Type I and Type II water purification systems.
Replacement water purification parts – filters and cartridges – are key components of these systems and must be changed according to specifications to maintain the promised water quality.
Filtered Search Results
Fisher Scientific™ Accu100 Ultrapure Water System
Ultrapure water for critical laboratory applications. Fisherbrand™ Accu100 Ultrapure Water System used to produce Type I ultrapure water from RO, distilled or deionized water.
Particle Size | <1/mL |
---|---|
Height (Metric) | 44 cm |
Flow Rate | 1.0 to 1.5 L/min. at 25°C |
Length (Metric) | 21 cm |
Depth (Metric) | 35 cm |
Resistivity | 18.2 Mohm.cm at 25°C |
Length (English) | 8.26 in. |
Model | Accu100 |
Feedwater Source | Distilled, DI, RO, EDI |
Temperature Range (Metric) | 5°C to 45°C |
Bacterial Content | <0.1 CFU/mL |
Height (English) | 17.3 in. |
Thermo Scientific™ Barnstead™ GenPure™ Pro Water Purification System
Produce Type 1 ultrapure water while conserving space with the compact and flexible Thermo Scientific™ Barnstead™ GenPure™ Pro Water Purification System.
Operating Pressure | 2 to 6 bar |
---|---|
Height (Metric) | 615 mm |
Electrical Requirements | 90/240 V 50/60 Hz |
Depth (English) | 18.6 in. |
Width (English) | 13 in. |
Resistivity | 18.2 Mohm.cm |
Conductivity | 0.055µS/cm |
Particles >0.2µM/mL | <1 |
TOC Monitor with UV Intensity Monitoring | Yes |
Width (Metric) | 330 mm |
Flow Rate | Up to 2 L/min. |
Type | Water Purification System |
Feedwater Connector | 3/4 in. NPT |
Depth (Metric) | 472 mm |
Product Water Type | Type 1 |
Voltage | 90/240 V |
Frequency | 50/60 Hz |
Temperature Range (Metric) | 2°C to 35°C |
Power Consumption | 0.1 kW |
Height (English) | 24.2 in. |
Feed Water Monitoring | Integrated |
Thermo Scientific™ Point of Dispense Filters for Barnstead™ Point of Use Water Purification Systems
Sterile filter for use with Barnstead™ water purification systems; can be autoclaved up to 5 times.
Fisherbrand™ Deionization Cartridges
Purify water with single use cartridges. Fisherbrand™ Deionization Cartridges change color when saturation is detected.
Flow Rate | 20 L/hr. |
---|---|
Type | Cartridge |
Capacity | Depends on the quality of the inlet water |
Quantity | 1 Each |
Temperature (Metric) Max. Operating | 35°C |
Temperature (Metric) Operating | 10°C to 35°C |
Pressure | 3 bar |
Filter Size | 500 mm |
Resin Type | Ion Exchanger |
Thermo Scientific™ Accessories for the Barnstead™ TII Type 2 Water System
Integrate the accessories for the Thermo Scientific™ Barnstear™ TII Type 2 Water System with the system itself for a more complete laboratory solution.
Feedwater Pressure | 30 to 100 psig (2 to 6.9 bar) |
---|---|
Height (Metric) | 49.5 cm |
Electrical Requirements | 100/240 VAC 50/60 Hz |
Depth (English) | 18.5 in. |
Width (English) | 13.5 in. |
RO Flow Rate | 12 L/hr. |
Resistivity | 15 Mohm.cm at 25°C |
Conductivity | 0.067 to 0.1 µS/cm |
Feedwater Source | Tap |
TOC Monitor with UV Intensity Monitoring | No |
Width (Metric) | 34.3 cm |
Total Organic Carbon | 1 to 5 ppb |
For Use With (Equipment) | Barnstead™ TII Type 2 Water System |
Depth (Metric) | 47 cm |
Product Water Type | Type 2 |
Voltage | 100/240 VAC |
Purified Water Flowrate Field | 1 L/min. |
Frequency | 50/60 Hz |
Feedwater Temperature (Metric) | 4°C to 40°C |
Bacterial Content | <1 CFU/mL |
Height (English) | 19.5 in. |
Fisherbrand™ Accu20 Ultrapure Water System
Fisherbrand™ Accu20 Ultrapure Water System used to produce Type I ultrapure water and RO water on demand from tap water directly.
Feedwater Pressure | 15 to 90 psi (1 to 6 bar ) |
---|---|
Height (Metric) | 48 cm |
Flow Rate | RO water (at 25°C ): >0.5L/min.; Ultrapure water ( Type I ) (at 25°C ): >0.5L/min. |
Depth (English) | 20 in. |
Length (Metric) | 30 cm |
Depth (Metric) | 51 cm |
Resistivity | 18.2 Mohm.cm |
Length (English) | 76.2 in. |
Model | Accu20 |
Conductivity | RO water at 25°C: Typically <20μS/cm |
Temperature Range (Metric) | 5°C to 45°C |
Height (English) | 18.8 in. |
Fisherbrand™ ACCU500 Water Purification System
Produces ultrapure and reverse osmosis water from tap water directly with no additional pre-treatment filters.
Thermo Scientific™ Barnstead™ LabTower™ TII Water Purification System
Convert tap water into high-purity water with the Thermo Scientific™ Barnstead™ LabTower™ TII Water Purification System, a complete solution integrating purification and tank.
Operating Pressure | 2 to 6 bar |
---|---|
Height (Metric) | 1500 mm |
Net Weight (Metric) | 66 kg |
Resistivity | 10 to 1 Mohm.cm |
Conductivity | 0.1 to 1.0μS/cm |
Feedwater Source | Tap |
TOC Monitor with UV Intensity Monitoring | No |
Width (Metric) | 450 mm |
Type | Water Purification System |
Feedwater Connector | 3/4 in. NPT |
Depth (Metric) | 580 mm |
Product Water Type | Type 2 |
Temperature Range (Metric) | 2°C to 35°C |
Bacterial retention | 99% |
Feed Water Monitoring | No |
Thermo Scientific™ Barnstead™ Classic Stills
Remove inorganic solids, organics, bacteria and pyrogens from your water with Thermo Scientific™ Barnstead™ Classic Stills.
Frequency | 50/60 Hz |
---|---|
Certifications/Compliance | UL, cUL |
Thermo Scientific™ Barnstead™ GenPure™ xCAD Water Purification System
This item is no longer available. The recommended replacement is Thermo Scientific™ Barnstead™ GenPure™ xCAD Plus.
Operating Pressure | 2 to 6 bar |
---|---|
Feedwater Pressure | 1 to 6 bar |
Height (Metric) | 615 mm |
Electrical Requirements | 90/240 V 50/60 Hz |
Resistivity | 18.2 Mohm.cm |
Conductivity | 0.055 µS/cm |
Particles >0.2µM/mL | <1 μM/mL |
Feedwater Source | Pretreated |
Width (Metric) | 372 mm |
Flow Rate | Up to 2 L/min. |
Type | Water Purification System |
Feedwater Connector | R 3/4 in. |
Depth (Metric) | 330 mm |
Voltage | 90/240 V |
Frequency | 50/60 Hz |
Temperature Range (Metric) | 2°C to 35°C |
Power Consumption | 0.1 kW |
Remote Dispenser | Yes |
Bacterial Content | <1 CFU/mL |
Feed Water Monitoring | Yes |
Thermo Scientific™ Barnstead™ Pacific™ RO Water Purification System
Improve functional and economical production of high-purity water with this modularly designed laboratory reverse osmosis system.
Operating Pressure | 1.5 to 6 bar |
---|---|
Height (Metric) | 603 mm |
Electrical Requirements | 230 V 50/60 Hz |
Net Weight (Metric) | 21 kg |
Width (Metric) | 372 mm |
Type | Reverse Osmosis Water Purification System |
Feedwater Connector | 3/4 in. NPT |
Depth (Metric) | 330 mm |
Voltage | 230 V |
Frequency | 50/60 Hz |
Temperature Range (Metric) | 2°C to 35°C |
Power Consumption | 0.1 kW |
Bacterial retention | 99% |
Feed Water Monitoring | Integrated |
Thermo Scientific™ Barnstead™ MicroPure™ Water Purification System
Process up to 15L/day of ultra-pure water with the compact Thermo Scientific™ Barnstead™ MicroPure™ Water Purification System, which reliably performs applications such as HPLC.
Operating Pressure | 0.1 to 6 bar |
---|---|
Feedwater Pressure | 1 to 6 bar |
Height (Metric) | 545 mm |
Electrical Requirements | 100/240 V 50/60 Hz |
Resistivity | 18.2 Mohm.cm |
Conductivity | 0.055μS/cm |
Particles >0.2µM/mL | <1 μM/mL |
Feedwater Source | Pretreated |
TOC Monitor with UV Intensity Monitoring | No |
Width (Metric) | 305 mm |
Type | Water Purification System |
Feedwater Connector | R 3/4 in. |
Product Water Type | Type 1 |
Voltage | 100/240 V |
Frequency | 50/60 Hz |
Temperature Range (Metric) | 2°C to 35°C |
Power Consumption | 0.06 kW |
Feed Water Monitoring | Yes |
Thermo Scientific™ Barnstead™ LabTower™ RO Water Purification System
Convert tap water into reverse osmosis water with integrated 100L storage using the Thermo Scientific™ Barnstead™ LabTower™ RO Water Purification System.
Operating Pressure | 2 to 6 bar |
---|---|
Feedwater Pressure | 1 to 6 Bar |
Height (Metric) | 1500 mm |
Net Weight (Metric) | 50 kg |
Particles >0.2µM/mL | <1 μM/mL |
Feedwater Source | Tap |
TOC Monitor with UV Intensity Monitoring | No |
Width (Metric) | 450 mm |
Silica Removal | 98% |
Type | Reverse Osmosis Water Purification System |
Feedwater Connector | 3/4 in. NPT |
Depth (Metric) | 580 mm |
Frequency | 50/60 Hz |
Temperature Range (Metric) | 2°C to 35°C |
Power Consumption | 0.25 kW |
Bacterial Content | 99% |
Feed Water Monitoring | Yes |
Thermo Scientific™ Cabinet Softening System WAE
Extend the life of reverse osmosis membranes. Single softening cabinet systems have time control and are specially designed for discontinuous use.
Type | Water Softening System, WAE |
---|---|
Depth (Metric) | 450 mm |