UV-Vis Spectrophotometers
UV-Vis Spectrophotometers
- (1)
- (6)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (7)
- (6)
- (3)
- (2)
- (1)
- (12)
- (17)
- (1)
- (2)
- (33)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (60)
- (9)
- (2)
- (2)
- (1)
- (8)
- (1)
- (8)
- (9)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (13)
- (1)
- (1)
- (2)
- (1)
- (35)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (3)
- (9)
- (3)
- (2)
- (1)
- (4)
- (20)
- (1)
- (2)
- (4)
- (1)
- (11)
- (2)
- (24)
- (2)
- (2)
- (3)
- (2)
- (16)
- (2)
- (14)
- (41)
- (3)
Filtered Search Results
Biochrom BioDrop Duo+
The BioDrop Duo+ is a Micro-Volume UV/Vis spectrophotometer with pre-programmed life science methods and general spectrophotometric capabilities. This 2-in-1 instrument will fulfill the needs of the most demanding laboratories.
Shape | Round |
---|---|
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Pathlength | 10 mm + 0.5 mm |
For Use With (Application) | General Spectrophotometry and Life Science Methodology |
Light Source | Xenon Flash |
Measurement Time | >4 Seconds |
Sample Volume (Metric) | Minimum 0.5 μL |
Type | Microvolume UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 280 x 410 x 190 mm |
Wavelength Accuracy | ±2 nm |
Voltage | 120/240 V |
Stray Light | <0.5 %T at 220 nm NaI; <0.5 %T (at 340 nm NaNO2) |
Weight (English) | 7.9 lb. |
Photometric Repeatability | ±0.003 A (0 to 0.5 A); ±0.007 A (0.5 to 1.0 A) |
Interface | Touch Screen Display (Color), USB Port |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3.6 kg |
Product Line | BioDrop Duo+ |
Display | Color Touchscreen |
Implen™ NanoPhotometer™ N60 Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N60 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, HDMI, Ethernet, WiFi |
---|---|
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ NP80 Nano-Volume and Cuvette UV-VIS Spectrophotometer
The Implen NanoPhotometer™ NP80 UV/Vis spectrophotometer for NanoVolume and cuvette applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, Ethernet, WiFi |
---|---|
Operating Temperature | 37 °C ± 0.5 °C Cuvette |
Beam Center Height | 8.5 mm |
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A NanoVolume, 0 to 2.6 A Cuvette |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Thermo Scientific™ GENESYS™ 40/50 Vis/UV-Vis Spectrophotometers
For teaching labs or quality control experts who require ruggedness, ease-of-use and software capability in UV-Vis spectrophotometry.
Biochrom BioDrop μLITE+ with Built-in Printer
The BioDrop μLITE+ microvolume sample port uses no moving parts. This means that the instrument provides excellent reproducibility without the need for expensive calibration, and no concern your results may stray over time.
Thermo Scientific™ GENESYS™ 140/150 Vis/UV-Vis Spectrophotometers
Get the most for your QA/QC or teaching lab with a rugged, network ready spectrophotometer designed for repetitive measurements and ease of use.
Cole-Parmer™ Jenway™ 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive™ Connectivity
Get cloud-based secure storage of your results and protocols with Jenway 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive Connectivity
Connections | 2 x USB-A, 1 x USB-B, Ethernet RJ45 |
---|---|
Photometric Range | 0 to 199.9 %T |
Wavelength Repeatability | ± 0.5 nm |
Spectral Bandwidth | 5 nm |
Absorbance Range | -0.3 to +2.5 A |
Pathlength | 10 to 100 mm |
Concentration | -300 to 9999 |
Includes | 10GB memory |
Detector Type | Silicon Photodiode |
Type | Spectrophotometer |
Dimensions (L x W x H) | 50 x 28 x 15.6 cm |
Wavelength Accuracy | ± 2 nm |
Photometric Accuracy Including Standard Tolerance | ±1%T |
Voltage | 100/240 V |
Absorbance Accuracy | ±0.01 A at 1.000 A |
Certifications/Compliance | CE |
Optical Design | Single |
Hertz | 50/60 Hz |
Display | Touchscreen |
Thermo Scientific™ Evolution™ Pro UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Spectral Bandwidth | 0.5, 1.0, 1.5, 2.0, 4.0 nm Selectable |
---|---|
Product Line | Evolution Pro |
Thermo Scientific™ SPECTRONIC 200™ Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the new standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Connections | USB-B for connection to a remote computer USB-A for connection to a printer or USB memory device |
---|---|
Width (English) | 15.3 in. |
Printer Included | External printer support: Epson TM-T88V |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese, Korean, Thai |
Photometric Readout | ABS, %T, Concentration (standard or custom units) |
Light Source | Tungsten Halogen |
Width (Metric) | 39 cm |
Includes | Two Cuvet Racks; Ten 1cm plastic cuvets |
Detector Type | 2048-element CCD |
Compartments | Removable, washable sample compartment |
Stray Light | <0.2%T (with SPECTRONIC standard SRM 400 filter) |
Optical Design | Single Beam |
Photometric Repeatability | ±0.03 A at 0.3 A |
Weight (Metric) | 5.2 kg |
Height (English) | 3.6 in. |
Height (Metric) | 16 cm |
Electrical Requirements | Selected automatically, 100/240 V, 50/60Hz |
Depth (English) | 11.8 in. |
Photometric Range | -0.3 to 2.5Å |
Wavelength Repeatability | ±1nm |
Data Interval for Scanning | 1 nm on-board, 0.5 nm under computer control |
Spectral Bandwidth | <4 nm |
Photometric Display | -0.3A - 2.5A; 0 - 125%T |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Depth (Metric) | 30 cm |
Keypad | Sealed tactile rubber |
Container Type | Single cell holder for square cuvettes and for test tubes |
Weight (English) | 9.7 lb. |
Interface | USB-B; USB-A |
Wavelength Range | 340 to 1000 nm |
Display | 3.5 in. Color Graphic TFT LCD |
Thermo Scientific™ Evolution™ One/One Plus UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Thermo Scientific™ GENESYS™ 180 UV-Vis Spectrophotometer, EU power cable
Perform UV-Vis measurements with a double beam with a reference cell position with the Thermo Scientific GENESYS 180 UV-Vis spectrophotometer.
Implen™ NanoPhotometer™ N120 Multichannel Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N120 scans up to 12 samples in just 20 seconds. Quantifying DNA, RNA and proteins has never been faster. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation. Recalibration-free patented technology Made in Germany.
Processor | Linux based NPOS |
---|---|
Spectral Bandwidth | <2.5 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.04 to 160 A |
Pathlength | 1 and 0.125 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 1.7 - 2.5 seconds |
Sample Volume (Metric) | 2 to 3.5 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 to 12 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 1% @ 240 nm using NaI |
Wavelength Range | 200 to 900 nm |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ N50-Touch Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N50 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation.
Lovibond™ Colorimeter Tablet Reagent: DPD No. 1
Use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba IIElectronic Pool Tester
Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer
Perform both basic and complex analyses with the Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer, an intuitive, reliable solution for education or in the lab.
Photometric Accuracy | ±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A) |
---|---|
Connections | USB-A, USB-B |
Scan Speed | Automatic – up to 1200 nm/min. |
Printer Included | Thermal printer accessory with 80 mm width paper |
Noise | ≤0.001A at 0A |
Languages | English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Detector Type | Silicon Photodiode |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100mm pathlength Available accessory for test-tubes up to 25mm diameter and 150mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Stray Light | <0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Optical Design | Single Beam |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A at 546 nm |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 1 nm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz |
Warranty | 2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase |
Photometric Range | -3A to +3A |
Wavelength Repeatability | < ±1 nm |
Spectral Bandwidth | 5 nm |
Baseline Flatness | <0.003 A, 325 to 1000 nm, smoothed |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Type | Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5x 38.5x 19.5 cm |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Keypad | Tactile rubber 23 keys with numeric keypad |
Drift | <0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup |
Wavelength Range | 325 to 1100 nm |
Product Line | GENESYS 30 |
Display | 5 in. 32-bit Color Display, 800 x 480 pixels |