UV-Vis Spectrophotometers
UV-Vis Spectrophotometers
- (1)
- (6)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (7)
- (6)
- (3)
- (2)
- (1)
- (12)
- (17)
- (1)
- (2)
- (33)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (60)
- (9)
- (2)
- (2)
- (1)
- (8)
- (1)
- (8)
- (9)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (13)
- (1)
- (1)
- (2)
- (1)
- (35)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (3)
- (9)
- (3)
- (2)
- (1)
- (4)
- (20)
- (1)
- (2)
- (4)
- (1)
- (11)
- (2)
- (24)
- (2)
- (2)
- (3)
- (2)
- (16)
- (2)
- (14)
- (41)
- (3)
Filtered Search Results
Implen™ NanoPhotometer™ N60 Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N60 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, HDMI, Ethernet, WiFi |
---|---|
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ NP80 Nano-Volume and Cuvette UV-VIS Spectrophotometer
The Implen NanoPhotometer™ NP80 UV/Vis spectrophotometer for NanoVolume and cuvette applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, Ethernet, WiFi |
---|---|
Operating Temperature | 37 °C ± 0.5 °C Cuvette |
Beam Center Height | 8.5 mm |
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A NanoVolume, 0 to 2.6 A Cuvette |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Biochrom BioDrop Duo+
The BioDrop Duo+ is a Micro-Volume UV/Vis spectrophotometer with pre-programmed life science methods and general spectrophotometric capabilities. This 2-in-1 instrument will fulfill the needs of the most demanding laboratories.
Shape | Round |
---|---|
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Pathlength | 10 mm + 0.5 mm |
For Use With (Application) | General Spectrophotometry and Life Science Methodology |
Light Source | Xenon Flash |
Measurement Time | >4 Seconds |
Sample Volume (Metric) | Minimum 0.5 μL |
Type | Microvolume UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 280 x 410 x 190 mm |
Wavelength Accuracy | ±2 nm |
Voltage | 120/240 V |
Stray Light | <0.5 %T at 220 nm NaI; <0.5 %T (at 340 nm NaNO2) |
Weight (English) | 7.9 lb. |
Photometric Repeatability | ±0.003 A (0 to 0.5 A); ±0.007 A (0.5 to 1.0 A) |
Interface | Touch Screen Display (Color), USB Port |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3.6 kg |
Product Line | BioDrop Duo+ |
Display | Color Touchscreen |
Thermo Scientific™ GENESYS™ 40/50 Vis/UV-Vis Spectrophotometers
For teaching labs or quality control experts who require ruggedness, ease-of-use and software capability in UV-Vis spectrophotometry.
Biochrom BioDrop μLITE+ with Built-in Printer
The BioDrop μLITE+ microvolume sample port uses no moving parts. This means that the instrument provides excellent reproducibility without the need for expensive calibration, and no concern your results may stray over time.
Thermo Scientific™ GENESYS™ 180 UV-Vis Spectrophotometer, EU power cable
Perform UV-Vis measurements with a double beam with a reference cell position with the Thermo Scientific GENESYS 180 UV-Vis spectrophotometer.
Thermo Scientific™ GENESYS™ 140/150 Vis/UV-Vis Spectrophotometers
Get the most for your QA/QC or teaching lab with a rugged, network ready spectrophotometer designed for repetitive measurements and ease of use.
Thermo Scientific™ Evolution™ Pro UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Spectral Bandwidth | 0.5, 1.0, 1.5, 2.0, 4.0 nm Selectable |
---|---|
Product Line | Evolution Pro |
Thermo Scientific™ Evolution™ One/One Plus UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Cole-Parmer™ Jenway™ 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive™ Connectivity
Get cloud-based secure storage of your results and protocols with Jenway 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive Connectivity
Connections | 2 x USB-A, 1 x USB-B, Ethernet RJ45 |
---|---|
Photometric Range | 0 to 199.9 %T |
Wavelength Repeatability | ± 0.5 nm |
Spectral Bandwidth | 5 nm |
Absorbance Range | -0.3 to +2.5 A |
Pathlength | 10 to 100 mm |
Concentration | -300 to 9999 |
Includes | 10GB memory |
Detector Type | Silicon Photodiode |
Type | Spectrophotometer |
Dimensions (L x W x H) | 50 x 28 x 15.6 cm |
Wavelength Accuracy | ± 2 nm |
Photometric Accuracy Including Standard Tolerance | ±1%T |
Voltage | 100/240 V |
Absorbance Accuracy | ±0.01 A at 1.000 A |
Certifications/Compliance | CE |
Optical Design | Single |
Hertz | 50/60 Hz |
Display | Touchscreen |
Thermo Scientific™ SPECTRONIC 200™ Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the new standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Connections | USB-B for connection to a remote computer USB-A for connection to a printer or USB memory device |
---|---|
Width (English) | 15.3 in. |
Printer Included | External printer support: Epson TM-T88V |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese, Korean, Thai |
Photometric Readout | ABS, %T, Concentration (standard or custom units) |
Light Source | Tungsten Halogen |
Width (Metric) | 39 cm |
Includes | Two Cuvet Racks; Ten 1cm plastic cuvets |
Detector Type | 2048-element CCD |
Compartments | Removable, washable sample compartment |
Stray Light | <0.2%T (with SPECTRONIC standard SRM 400 filter) |
Optical Design | Single Beam |
Photometric Repeatability | ±0.03 A at 0.3 A |
Weight (Metric) | 5.2 kg |
Height (English) | 3.6 in. |
Height (Metric) | 16 cm |
Electrical Requirements | Selected automatically, 100/240 V, 50/60Hz |
Depth (English) | 11.8 in. |
Photometric Range | -0.3 to 2.5Å |
Wavelength Repeatability | ±1nm |
Data Interval for Scanning | 1 nm on-board, 0.5 nm under computer control |
Spectral Bandwidth | <4 nm |
Photometric Display | -0.3A - 2.5A; 0 - 125%T |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Depth (Metric) | 30 cm |
Keypad | Sealed tactile rubber |
Container Type | Single cell holder for square cuvettes and for test tubes |
Weight (English) | 9.7 lb. |
Interface | USB-B; USB-A |
Wavelength Range | 340 to 1000 nm |
Display | 3.5 in. Color Graphic TFT LCD |
Thermo Scientific™ BioMate™ 160 UV-Vis Spectrophotometer
Perform automated measurements of nucleic acids, proteins and cell cultures with the Thermo Scientific BioMate 160 UV-Vis spectrophotometer.
Spectral Bandwidth | 2 nm |
---|
Jenway™ Variable Double Beam Spectrophotometer
Use this spectrophotometer for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA/RNA and protein analysis. Jenway™ Variable Double Beam Spectrophotometers feature highly stable optics and two detectors, optimizing measurement accuracy.
Implen™ NanoPhotometer™ N50-Touch Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N50 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation.
Implen™ NanoPhotometer™ N120 Multichannel Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N120 scans up to 12 samples in just 20 seconds. Quantifying DNA, RNA and proteins has never been faster. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation. Recalibration-free patented technology Made in Germany.
Processor | Linux based NPOS |
---|---|
Spectral Bandwidth | <2.5 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.04 to 160 A |
Pathlength | 1 and 0.125 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 1.7 - 2.5 seconds |
Sample Volume (Metric) | 2 to 3.5 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 to 12 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 1% @ 240 nm using NaI |
Wavelength Range | 200 to 900 nm |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |