UserName
BrightComp eBeads compensation beads provide a consistent, accurate, and simple-to-use technique for setting flow cytometry compensation when using fluorescent protein-expressing samples.
Product Type | Compensation Beads |
---|---|
Quantity | 25 tests |
For Use With (Application) | Flow Cytometry |
Provides a consistent, accurate, and simple-to-use technique for the setting of flow cytometry compensation when using fluorochrome-conjugated mouse, rat, hamster, or rabbit antibodies with any laser in flow cytometry.
Shipping Condition | Room Temperature |
---|---|
Content And Storage | Contains 1 vial AbC™ Total Compensation capture beads and 1 vial of negative beads. |
Format | Tube |
For Use With (Equipment) | Flow Cytometer |
Product Type | Compensation Beads |
Diameter (Metric) | 6 μm |
Excitation Wavelength Range | any lasers (UV to 633/635) |
Product Line | AbC™ |
Detection Method | Fluorescence |
ArC™ Amine Reactive Compensation Bead Kit (for use with LIVE/DEAD™ Fixable dead cell stain kits)
Shipping Condition | Room Temperature |
---|---|
Format | Tube |
For Use With (Equipment) | Flow Cytometer |
Product Type | Compensation Beads |
Diameter (Metric) | 6 μm |
Stain Configuration | Surface |
Quantity | 1 Kit |
Detection Method | Fluorescence |
CountBright™ Absolute Counting Beads, for flow cytometry
Flow Cytometry Sub-micron Particle Size Reference Kit
Flow Cytometry Size Calibration Kit (nonfluorescent microspheres)
Provide greater durability and chemical stability when using solvents with these monodisperse silica microspheres used in instrument calibration and as spacers.
Product Type | Silica Particle Size Standard |
---|
Alignflow™ Flow Cytometry Alignment Beads for Red Lasers, 2.5 μm
Calibrated suspension of ∼4 μm beads that encapsulate dyes that are excitable across a wide range of UV-IR wavelengths and brightly fluoresce in the emission range of 385-860 nm.
Can be used to fix and permeabilize cells prior to performing intracellular staining of cytokines and other cytoplasmic and/or nuclear antigens.
The eBioscience™ Mouse Intracellular (cytoplasmic/cytokine) Protein Flow Cytometry Workflow Kit contains all of the normal buffers, blockers, and beads needed to complete a standard flow cytometry experiment for staining intracellular cytoplasmic and cytokine targets in mouse cell suspensions.
Cell Sorting Set-up Beads (for UV lasers)
Alignflow™ Flow Cytometry Alignment Beads for Red Lasers, 6.0 μm
Intended for use in absolute counting of cells or other particles by flow cytometry. 123count eBeads are 7μm microparticles containing encapsulated dyes compatible with blue (488nm) and violet (405nm) excitation sources and emitting fluorescence between approximately 500nm and 750nm.
CountBright Plus Ready Tubes offer the same advantages as CountBright Plus Absolute Counting Beads, but in ready-to-use tubes. This not only improves the accuracy and repeatability of cell counting, but also allows for convenient room temperature storage for up to 12 months.