
Shipping Condition | Room Temperature |
---|---|
Product Type | Fixation/Permeabilization Reagent |
Product Line | FIX & PERM™ |
Invitrogen™ AbC™ Total Antibody Compensation Bead Kit
Provides a consistent, accurate, and simple-to-use technique for the setting of flow cytometry compensation when using fluorochrome-conjugated mouse, rat, hamster, or rabbit antibodies with any laser in flow cytometry.

Shipping Condition | Room Temperature |
---|---|
Content And Storage | Contains 1 vial AbC™ Total Compensation capture beads and 1 vial of negative beads. |
Format | Tube |
For Use With (Equipment) | Flow Cytometer |
Product Type | Compensation Beads |
Diameter (Metric) | 6 μm |
Excitation Wavelength Range | any lasers (UV to 633/635) |
Product Line | AbC™ |
Detection Method | Fluorescence |
Thermo Scientific™ MitoProbe™ TMRM Assay Kit for Flow Cytometry
The MitoProbe TMRM Assay Kit contains tetramethylrhodamine methyl ester (TMRM) for the detection of mitochondrial membrane potential state and CCCP for the induction of mitochondrial membrane depolarization, if desired.

Invitrogen™ CellTrace™ CFSE Cell Proliferation Kit, for flow cytometry
CellTrace™ CFSE Cell Proliferation Kit is used for in vitro and in vivo labeling of cells to trace multiple generations using dye dilution by flow cytometry.

Shipping Condition | Room Temperature |
---|---|
Format | Tube(s) |
Product Type | Cell Proliferation Kit |
For Use With (Equipment) | Flow Cytometer |
Emission | 488 nm |
Product Line | CellTrace™ |
Detection Method | Fluorescence |
Invitrogen™ CellBlox™ Blocking Buffer
Formulated to block nonspecific binding of Invitrogen™ NovaFluor™ labels with cells, which can result in higher background labeling. Also recommended for cyanine-based dyes or cyanine-based tandem dyes to block non-specific interactions with monocytes and macrophages to minimize background labeling.

Description | Blocking Buffer |
---|---|
For Use With (Application) | Flow Cytometry |
Invitrogen™ CellTrace™ Yellow Cell Proliferation Kit, for flow cytometry
CellTrace™ Yellow Cell Proliferation Kit is used for in vitro and in vivo labeling of cells to trace multiple generations using dye dilution by flow cytometry.

Shipping Condition | Room Temperature |
---|---|
Format | Tube(s) |
Product Type | Cell Proliferation Kit |
For Use With (Equipment) | Flow Cytometer |
Dye Type | CellTrace™ Yellow |
For Use With (Application) | Proliferation Assay |
Product Line | CellTrace™ |
Detection Method | Fluorescence |
Invitrogen™ eBioscience™ IC Fixation Buffer
Can be used to fix cells prior to permeabilization with the Permeabilization Buffer (cat. 00-8333) when performing intracellular staining of antigens located in the cytoplasm and secretory pathway, such as cytokines, chemokines and growth factors.

Invitrogen™ eBioscience™ Permeabilization Buffer (10X)
Can be used to fix and permeabilize cells prior to performing intracellular staining of cytokines and other cytoplasmic and/or nuclear antigens.

Invitrogen™ UltraComp eBeads™ Compensation Beads
Designed for use in compensation with all fluorochromes excited by ultraviolet, violet, blue, green, yellow-green, and red lasers. UltraComp eBeads™ react with antibodies of mouse, rat, and hamster origin, and are immunoglobulin light chain-independent. 1 drop (50μL)/test.

For Use With (Equipment) | Flow Cytometer |
---|---|
Product Type | Compensation Beads |
Product Line | eBeads™ |
Invitrogen™ eBioscience™ Fixation/Permeabilization Diluent
Intended to be used with antibodies to transcription factors and nuclear proteins, such as Foxp3 and Ki-67, as well as cytokines and chemokines.

Invitrogen™ UltraComp eBeads™ Plus Compensation Beads
UltraComp eBeads Plus Compensation Beads are the second generation of UltraComp beads for use in flow cytometry.
Product Type | Compensation Beads |
---|
Invitrogen™ eBioscience™ Flow Cytometry Staining Buffer
A buffered saline solution containing fetal bovine serum and sodium azide (0.09%) as a preservative. Designed for use in immunofluorescent staining protocols of cells in suspension.

Product Type | Staining Buffer |
---|---|
Product Line | eBioscience™ |
Invitrogen™ 123count eBeads™ Counting Beads
Intended for use in absolute counting of cells or other particles by flow cytometry. 123count eBeads are 7μm microparticles containing encapsulated dyes compatible with blue (488nm) and violet (405nm) excitation sources and emitting fluorescence between approximately 500nm and 750nm.

Invitrogen™ eBioscience™ Cell Stimulation Cocktail (plus protein transport inhibitors) (500X)
Can be used for induction and subsequent intracellular detection of cytokines and other secreted proteins in both in vitro-cultured and ex vivo cells

Product Type | Cell Stimulation Cocktail |
---|---|
For Use With (Application) | Flow Cytometry, Functional Assays, Cell Culture |
Product Line | eBioscience™ |
Invitrogen™ ArC™ Amine Reactive Compensation Bead Kit (for use with LIVE/DEAD™ Fixable dead cell stain kits)
ArC™ Amine Reactive Compensation Bead Kit (for use with LIVE/DEAD™ Fixable dead cell stain kits)
Shipping Condition | Room Temperature |
---|---|
Format | Tube |
For Use With (Equipment) | Flow Cytometer |
Product Type | Compensation Beads |
Diameter (Metric) | 6 μm |
Stain Configuration | Surface |
Quantity | 1 Kit |
Detection Method | Fluorescence |